Fix ERPNext and Forgejo probes

- ERPNext: custom blackbox module with Host: performancewest.net header
  (ERPNext multitenancy requires site name in Host for routing)
- Forgejo: add extra_hosts to blackbox-exporter so it can resolve
  host.docker.internal to reach forgejo on port 3000
- Blackbox http_erpnext module: sets Host header, expects 200

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
justin 2026-05-01 03:35:45 -05:00
parent f856434642
commit b190bcef92
3 changed files with 15 additions and 2 deletions

View file

@ -386,6 +386,8 @@ services:
image: prom/blackbox-exporter:latest
volumes:
- ./monitoring/blackbox.yml:/etc/blackbox_exporter/config.yml:ro
extra_hosts:
- "host.docker.internal:host-gateway"
restart: unless-stopped
volumes:

View file

@ -20,6 +20,17 @@ modules:
follow_redirects: false
preferred_ip_protocol: ip4
# ERPNext requires Host header matching the site name
http_erpnext:
prober: http
timeout: 10s
http:
valid_http_versions: ["HTTP/1.1", "HTTP/2.0"]
valid_status_codes: [200]
headers:
Host: performancewest.net
preferred_ip_protocol: ip4
tcp_connect:
prober: tcp
timeout: 5s

View file

@ -125,11 +125,11 @@ scrape_configs:
- target_label: __address__
replacement: blackbox-exporter:9115
# ── ERPNext CRM (login page returns 200) ───────────────────────────
# ── ERPNext CRM (requires Host header for site routing) ─────────────
- job_name: pw_erpnext
metrics_path: /probe
params:
module: [http_internal]
module: [http_erpnext]
static_configs:
- targets:
- http://erpnext:8000/api/method/ping